Comprehensive Guide to the XMTG-2000 Temperature Controller The is a widely used industrial instrument known for its reliability and precision. Whether you are setting up a new kiln, oven, or plastic injection machine, understanding how to navigate this controller is essential for maintaining consistent thermal environments.
To configure the controller, follow these common programming steps: Setting the Target Temperature (SV) Press the key once briefly. The SV display will flash.
Used to increase or decrease values.
When looking at the rear of the XMTG-2000, the terminal numbering usually follows this standard layout (always verify with the diagram printed on your specific unit’s casing): Terminals 1 and 2 (Standard AC input). Relay/SSR Output: Terminals 3, 4, and 5. Sensor Input: Thermocouple: Terminals 8 (+) and 9 (-). RTD (Pt100): Terminals 7, 8, and 9. Alarm: Terminals 6 and 7 (depending on model variation). 3. Front Panel Controls
Proportional, Integral, and Derivative constants for PID tuning. Sn (Sensor Type): 0 = K thermocouple; 21 = Pt100. SC (Sensor Calibration): Used to offset temperature errors. 5. Auto-Tuning (AT) xmtg-2000 temperature controller manual pdf
Moves the cursor to the digit you wish to change for faster setting. 4. How to Program the XMTG-2000
If your temperature is overshooting or oscillating, use the function. Enter the parameter menu and find the AT setting. Change the value to 1 or on . The SV display will flash
Check if the "OUT" light is blinking. If it is, the controller is sending a signal, but your heater or SSR may be faulty.
Displays the current measured temperature in red. SV (Set Value): Displays the target temperature in green. SET Key: Used to enter parameter menus and confirm changes. Relay/SSR Output: Terminals 3, 4, and 5